What is an egress window and why is it required?

An egress window, also known as an Emergency Escape and Rescue Opening (EERO), is a window designed to provide a safe exit from a basement or sleeping room in an emergency S1. These windows are crucial for ensuring occupants can escape and rescue personnel can enter a dwelling during an emergency S4.

All sleeping rooms and basements must have egress windows S1. If a basement has at least one sleeping room, then each sleeping room needs an emergency escape and rescue opening S4. These openings must open directly onto a public way, or a yard or court that offers a clear path to a public way S2.

The requirement for egress windows is based on codes such as the 2020 Minnesota Residential Code (R310) and the International Residential Code (IRC) S1S4. The 2020 Minnesota Residential Code adopts the 2018 International Residential Code with amendments S4. The International Code Council (ICC) develops the IRC, which is widely adopted in the United States S5.

Some basements might be excused from the egress window rules. Basements that only house mechanical equipment and have a total floor area no more than 200 square feet (18.58 square meters) do not need an emergency escape and rescue opening S2S4.

Homes that have a sprinkler system installed automatically may follow different egress rules for basement sleeping rooms. In these situations, basement sleeping rooms do not need emergency escape and rescue openings if the basement has either a single means of egress plus one emergency escape and rescue opening, or if it has two means of egress S2S4.

What are the minimum size requirements for an egress window?

To function as a viable emergency escape and rescue route, an egress window must meet certain minimum size criteria S3. The unobstructed space available when the window is fully open, termed the "net clear opening," needs to measure at least 5.7 square feet (0.530 m2) S1, S3. This measurement excludes the rough opening or the glass dimensions and refers solely to the usable escape area S3.

Beyond the total area, there are minimum requirements for the individual dimensions of the opening. The minimum opening width must be 20 inches (508 mm) S1, S3. Additionally, the minimum opening height must be 24 inches (610 mm) S1, S3. These dimensions are crucial to allow for the passage of an adult or emergency personnel S4.

The sill height, which is the lowest point of the clear opening, is another crucial dimension. It must be positioned no higher than 44 inches above the finished floor S1 to guarantee easy access for escape without the need for assistance or special tools S4.

Although 5.7 square feet is the typical requirement, certain circumstances permit a reduced net clear opening of at least 5 square feet (0.465 m2) for openings at grade or below grade S3. This allowance typically applies to basement windows or similar openings at ground level. The International Residential Code (IRC), which serves as a model code for many U.S S3. regions, details these regulations S4, S5.

What are the requirements for window wells?

If an emergency escape and rescue opening is located below ground level, a window well must be installed S1. These window wells are subject to specific dimensions and requirements under the 2020 Minnesota Building Code R310.2.3 S1.

Window wells are required to have a minimum area of 9 square feet S1. Additionally, they must extend at least 3 feet out from the building's foundation S1. Proper drainage is also a critical requirement for window wells S1.

For window wells deeper than 44 inches, a ladder or steps must be included to facilitate escape S1. The window well should also be positioned at least 2 feet away from any side or rear property line S1.

Devices such as bars, grilles, or grates can be installed on emergency escape windows or window wells, provided they meet certain conditions S1. These devices must be equipped with release mechanisms that can be opened from the inside without requiring a key, special knowledge, or significant effort S1. Furthermore, the building must have smoke and carbon monoxide alarms installed in accordance with Section 314 of the 2020 MN Residential Code S1. Any specific security grill systems require approval before installation S1.

Where are egress windows required in a basement?

Egress windows are required in all basements and every sleeping room within a basement S1, S4. These emergency escape and rescue openings are mandated by codes such as the 2020 Minnesota Residential Code (2020 MNRC) S1, S4. The Minnesota State Building Code, which includes the 2020 MNRC, applies throughout Minnesota S4. This code adopts the 2018 International Residential Code (IRC) with amendments S4. The IRC is a model building code created by the International Code Council (ICC) and is widely adopted in the United States S5. These openings are essential for allowing occupants to escape quickly and for emergency responders to enter a dwelling S4. Basements used solely for mechanical equipment and not exceeding 200 square feet are an exception to this requirement S2, S4. Similarly, storm shelters are also exempt S2, S4.

Each sleeping room in a basement must have an emergency escape and rescue opening, according to code S2, S4. However, this requirement does not apply to adjacent basement areas S4.

Emergency escape and rescue openings must lead directly outside to a street, or to a yard or court S2, S4. This exterior space must offer a clear passage at least 36 inches (914 mm) wide that connects to a public way S2. Obstructions do not include gates with release mechanisms that don't need keys, tools, or special knowledge to operate S2. Additionally, window wells equipped with a removable cover that complies with Section R310.4.4 of the code are also not considered obstructions S2.

Do I need a permit to install an egress window?

A permit is generally required to install an egress window S1. The 2020 Minnesota Residential Code (2020 MNRC) mandates that emergency escape and rescue openings be installed in accordance with its provisions, which are based on the 2018 International Residential Code (IRC) with amendments S4. These requirements apply throughout Minnesota, regardless of whether a local code enforcement office is present S4.

Installing an egress window, however, does not automatically authorize the creation of an additional dwelling unit or legalize a basement bedroom that was constructed without a permit S1. The primary purpose of these openings is to allow occupants to escape quickly and enable emergency responders, equipped with protective gear, to enter the dwelling S4.

Additional permits are necessary for other modifications to the basement beyond just the egress window installation S1. For example, if you plan to finish a room, add a bedroom, or create an additional dwelling unit in the basement, separate permits will be required for each of these projects S1. These regulations ensure that all structural and safety standards are met for any significant changes to your home.

For more information on general remodeling costs, you might find our article on Bathroom Remodel Costs: Breakdown and Tub-to-Shower Conversion helpful, as it discusses various project expenses.

What codes govern egress window installation?

Egress window requirements are primarily governed by local building codes, which frequently adopt the International Residential Code (IRC) with local amendments S1S4. The International Code Council (ICC), a non-profit organization, develops model building codes like the International Building Code (IBC) and the International Residential Code (IRC) S5. Most jurisdictions in the United States use these model codes as a foundational standard S5.

For instance, the 2020 Minnesota Residential Code (MNRC) incorporates the 2018 International Residential Code (IRC) along with specific amendments S4. This state-level code sets the construction standards for all of Minnesota, regardless of whether a local code enforcement agency is present S4. The Minnesota State Building Code, which includes the 2020 MNRC, is adopted under Minnesota Statutes, section 326B.106, subdivision 1, and its chapters are identified in Minnesota Rules, part 1300.0020 S4.

These codes mandate that basements, habitable attics, and all sleeping rooms must have at least one operable emergency escape and rescue opening S2S3S4. If a basement contains multiple sleeping rooms, each room requires an emergency escape and rescue opening S2S4. The purpose of these openings is to allow occupants to exit quickly and to enable emergency responders, equipped with protective gear, to enter the dwelling S4.